What was found
PWS WARNING AS TO THRUST WAS APPLIED UPDATED MAA CODE FIX USING VENDOR MAA SCREEN PLEASE CONTACT TOMC BEFORE COMMENCING ANY WORK. PERFORMED FIM 34-43 TASK 815 FOR PREDICTIVE WINDSHEAR, NO FAULTS SPEED REJECTED TAKE OFF LESS THAN 60 KTS. REALIGNED ADIRU''S FOUND. PERFORMED WX RADAR BITE PER FIM 34-43 TASK 801, NO PERFORMED WX RADAR TEST AGAIN, NO FAULTS. NO HISTORY. FAULTS. PERFORMED A/T BITE PER FIM 22-31 TASK 801, NO FAULTS. PERFORMED EEC BITE PER FIM 22-31- TASK 806, NO FAULTS. LOW ADDED MECHANICS EMPLOYEE NUMBER, MAC METER FAILED TO SEND ADD EMP:V7604118