What was found
FOUND 2EA CRACKS IN VERTICAL PRESSURE WEB AT STA 663.75 AND APPROX LBL 33. REF FLEET CYCLE N/R 9793198.CARD COMPLETE SEE WIPS AND TASKS FOR WORK PERFORMED.PER AMM 57-10-10-2R-3 REPAIR 3 ALTERNATIVE DIP 57-DIP NO TASK AND LIMITATIONS ENTERED INTO CORRECTIVE ACTION. ALL INSPECTIONS COMPLETED REFERENCE FLEETCYCLE N/R 9793198. ADD EMP:U180693 U248732 U248935 REQUIREMENTS PER SRM 57-10-10-2R-3 ALT. 1 TABLE 204 PG 6. INSTALLATION. HFEC AND LFEC INSPECTIONS AT INTERVAL OF 36,000 INSPECTION THRESHOLD: 56,000 FLIGHT CYCLES AFTER REPAIR FLIGHT CYCLES. REPAIRED PER SRM 57-10-10-2R-3 ALT. 1. REF. F/C N/R 9793198 FOR ALL WORK PERFORMED. . PLACED ON DIP TO PERFORM INSPECTION APPROVED TO PERFORM AN INSPECTION HFEC AND LFEC WITH AN INITIAL TOMC-APPROVAL FROM SC1ELBYC COMMENT THRESHOLD OF OF 56,000 FLT CYCLES WITH REPEAT INSPECTIONS EVERY 36,000 FLY CYCLES IN REFERENCE WITH SRM 57-10-10-2R-3. TOMC APPROVED : QC REVIEWED. ACCOMPLISHED SFR #1027345 TOMC APPROVED : QC REVIEWED. INSPECTIONS CREATED BY AUTODIP PENDING AIRCRAFT RECORDS AUDIT & UPDATE.