As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
RH- FR66, DOOR STOP #6, LOWER INBOARD HOLE HAS CRACK INDICATION. () SUPPORT TASK AD 2018-03-12 R/H FR66 #6DOOR STOP LOWER I/B HOLE. REPAIRED AND REAMED IAW SRM FORM 44-0008 ATTACHED. EMP# V934344 WORK ACCOMPLISHED AT ST ENGI 53-14-12-300-10. ORG. REAMED .394 FINAL DIA .421 NO CRACK NOTED NEERING AEROSPACE OF MOBILE AT BFM ON NR# 0021095 IAW NTM 51-10-01-PT6. FABRICATED AND INSTALLED FREEZE PLUG AND WASHER IAW SRM 53-73-12-001. REINSTALLED DOOR STOP FITTING #6