As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
(REPAIR BEFORE NEXT FLIGHT) VISUAL AND ROTO PROBE INSPECTION OF LH FR68 #7 DOOR STOP FITTING FASTENER HOLES FOUND #2 AND #4 HOLE S OUT OF ROUND.() REPAIRED LH FR68 #7 DOOR STOP IAW EC/RA 5341-01294 FORM 44-0008 ATTACHED. EMP# V935774 WORK ACCOMPLISHED AT ST ENGINEEERING AERO SPACE OF MOBILE AT BFM ON NR# 0018924