What was found
ON LAND CHECKLIST FLAPS SET TO 40 BUT DIDNT GO P AST 25 AFTER CHECKLIST FLAPS OPERATE NORMAL UPDATED MAA CODE FIX USING VENDOR MAA SCREEN UPDATED MAA CODE FIX USING VENDOR MAA SCREEN MAC METER INITIATED FOR. MAC RELATED WORK ORDER 000000003031273 AND PRTR, ACCOMPLISHED BITE CHECK OF FSCU PER AMM 27-51-00 , NO CURRENT LEG FAULTS NOTED. CYCLED FLAPS MUILTIPLE TIMES, OPS CHECKS ARE GOOD. ACFT GOOD FOR SERVICE. ACCOMPLISHED BITE CHECK OF FSCU PER AMM 27-51-00 , NO CURRENT LEG FAULTS NOTED. CYCLED FLAPS MUILTIPLE TIMES, OPS CHECKS ARE GOOD. ACFT GOOD FOR SERVICE.