What was found
FOUND 2 AREAS OF CORROSION DAMAGE IN THE AFT CARGO COMPARTMENT O N THE INTERIOR LEDGE BETWEEN FR57 AND FR58. (SDR) REMOVED CORROSION LEDGE BETWEEN FR57/FR58 IAW SRM 51-24-00, CHEC SRM 51-23-11. EMP: V936136 WC: 0024017 STA: ST ENG BFM KED LIMITS IAW SRM 53-41-44-283-003, OUT OF LIMITS. REMOVED SHEE T-THRESHOLD IAW SRM 51-42-11 AND INSTALLED NEW PART IAW SRM 51-4 2-11, TREATED NAD PRIMED IAW SRM 51-21-11, TOP COATED AREA IAW