What was found
PDA 2 L ENG OIL SERVICE ACCESS DOOR MISSING PANEL REFITTED WITH TEMP REPAIR IAW ECRA ON WALK AROUND FOUND L ENGINE OIL SERVICE DOOR MISSING. DOOR WAS TOMC-APPROVAL FROM SC1ELBYC COMMENT RECOVERED AND RETURNED TO AIRCRAFT. PER ECRA 7110-01125 COMPLY WITH TEMP REPAIR DISPOSITION. PRIOR TO EACH DEPARTURE INSPECT REPAIR FOR SEVICEABILITY. WITHIN 5 CYCLES COMPLETE PERMANENT REPAIR. ADDING PHOTOS TOMC APPROVED : QC REVIEWED. RECORDS UPDATE TOMC APPROVED : QC REVIEWED. RIR: M-METER PRIOR TO EACH DEPARTURE (NO M&E RQRD) T/A: WITHIN 5 FC.....LN TOMCQC REV PERFORMED REMOVED AND REPLACED DAMAGED HINGE AND DOOR REF SR 51-40-02