As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
(AD2022-02-11) DURING ROTO PROBE RH FR16 DOOR STOP #7 FOUND HOLE S #1 & #3 WITH CRACK INDICATIONS IN INTERCOSTAL AND FRAME LAYERS REPAIR BEFORE NEXT FLIGHT (REPAIR IAW R53113118 & ECRA AS REQUI RED) REPAIRED RH FR16 DOOR STOP #7 HOLE''S 1 & 3 BY INTERCOSTAL REPLAC EMENT & OVERSIZED BOLT INSTALLATION IAW EC/RA 5311-02799. ACCOMP LISHED BY EMP#V935774 AT BFM ST AEROSPACE MOBILE NR#0027077