As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
A3NB-53-3-6183: CORROSION ONLY AFT ENTRY DOOR, LOWER SILL PLATE, GIRT BAR FITTING PLATE. DOT 66-05.() REMOVED CORROSION ON LH ENTRY DOOR LOWER SILL IAW SRM 51-74-00. 51-42-11. FORM 44-0008 ATTACHED EMP# V933866 WORK ACCOMPLISHED A MEASURED AT THICKNESS:0315" MEASURING THICKNESS:.215" D=.100" L= T ST ENGINEERING AEROSPACE OF MOBILE AT BFM ON NR# 0029710. 2.5" W=5" DOOR SILL FOUND WITHOUT OF LIMITS IAW SRM 53-41-14-283 FIG 2. REMOVED AND REPLACED DOOR SILL IAW SRM 51-44-11 AND SRM