As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AD2022-02-11 DURING ROTO PROBE LH FR16 DOOR STOP #7 FOUND HOLES #1 & #3 WITH CRACK INDICATIONS IN INTERCOSTAL AND FRAME LAYER. R EPAIR BEFORE NEXT FLIGHT (REPAIR IAW R53113118 & ECRA AS REQUIRE D) REPAIRED L/H FR16 DOOR STOP #7 HOLES #1 & #3 BY INTERCOSTAL REPL ACEMENT & FRAME BUSHING IAW EC/RA 5311-02799. ACCOMPLISHED BY EM P#V935774 AT BFM ST AEROSPACE MOBILE. NR#0027076