What was found
FR66 RHS AFT DOOR STOP FITTING #1 TO #7 HOLES FOUND BEYOND THE REQUIRED STARTING HOLE DIAMETER OF 8-1-N AS PER EA 5340-01724 REV.C OPERATION 001 STEP 6.2 FIGURE 01 SHEET 02. ZONE:260 SEQ:1602. LTPR NR# 5001155213-0010. RPR IS CONSIDERED CAT B. REINSPECT IAW SRI 53-41-12-205-008. CLASSIFIED AS PERMENANT WITH FOLLOW-ON REINSPECTIONS. CURRENT PTC 29837. INSPECT THRESHOLD 56600 FC, INTERVALS 18600. PERFORMED RPR ON FR66 RH DOOR STOP FITTING ATTACHMNT HOLES 1-7 IAW SRM 53-41-12-300-009. HOLES OVERSIZED TO 2ND OVER. OK TO CARRY INSPECTION OF REPAIR TO AFT DOOR STOP FITTINGS #1-#7 TOMC-APPROVAL FROM SC1ELBYC COMMENT FOR 56600 FLT CYCLES (FLT HRS NOT RELEVANT) FROM REPAIR EMBODIMENT, WITH RECHECK REQUIREMENT EVERY 18600 FLT CYCLES (FLT HRS NOT RELEVANT) THEREAFTER PER SRM 53-41-12-300-009 AND SRI53-41-12-205-008 FITTING FINAL HOLE SIZE 0.283". FINAL HOLE SIDE ON AIRCRAFT FRAME 0.281". QC REVIEWED QC REVIEWED INIT: 56600 FC INIT WILL AUTO ITO TO -4648 RIR: 18,600 FC THEREAFTER...SN RECORDS UPDATE RECORDS UPDATE