What was found
RUDDER HINGE BEARINGS/FITTINGS BR1 AND BR5 HAVE EXCESSIVE PLAY. LTPR NR# 5001148819-0010 AT 60000FC FROM TIME OF COMPONENT FIRST FLIGHT, SUBSEQUENT SRI 55-36-42-205-004 INSPECTION INTERVALS AND METHOD OF INSPECTION ARE TBD IAW RUDDER HINGE FITINGS ASSY''S BR 1 AND BR 5 REPLACED IAW SRM 55-36-42-300-008, CAT "B" MAJOR REPAIR, INSPECTION THRESHOLD REF SRI 55-36-42-205-004 INSPECTION THRESHOLD FROM COMPONENT TOMC-APPROVAL FROM SC1ELBYC COMMENT FIRST FLIGHT 60000 FC (FH NOT REVELANT) SUBSEQUENT INSPECTION INTERVALS AND METHOD OF INSPECTION TBD. TOMC APPROVES DIP. Q/C REVIEWED. Q/C REVIEWED. INSPECTIONS CREATED BY AUTODIP PENDING AIRCRAFT RECORDS AUDIT & UPDATE.