What was found
RH FR 68 AT STR 22 FLANGE HAS CRACK INDICATION IN RADIUS PER HAE CO LCQ NON ROUTINE 9294407/36407 GENERATED BY V892444 68 STR 22-24 REPAIR PER PART2 ITEM 1&4 OF LATEST REV OF ECRA5341 T TO EXCEED19700FC THEREAFTER. ACCOMPLISH INITIAL INSP OF RH FR REV OF ECRA 5341-01318 ON/BEFORE 66000 TTL FC. SEE ALSO LP 8662 -01318 ON/BEFORE 49651 TTL FC. ACCMP REPEAT INSP AT INTERVALS NO 68 DOOR STOP FITTING #1 REST OF AREA PER PART2 ITEM 2 OF LATEST 861 ACCMP''D INTERIM REPAIR PER PART 1 OF ECRA5341-01318 & REO L23773 W/ NO DEVIATIONS. DIP REQ''D TO ACCOMPLISH INITIAL INSP AT RH FR DIP 53-DIP REJ NEED TO HAVE 2 SEPERATE DIPS FOR THE LIMTIS PER ECRA APPROVED CLEAR ITEM AND REGENERATED LP''S 8707450 AND 8707536 TO CARRY MULTIPLE LIMITS FOR ONE DEFECT, AS REQUIRED BY ECRA5341-01318 AND REO L23773