What was found
ENG 2 OVERHEAT LIGHT LIGHT IS ON R ENG OVERHEAT LT ILLUMINATED CLIMBING THRU 10000 FEET UPDATED MAA CODE FIX USING VENDOR MAA SCREEN PLEASE CONTACT TOMC BEFORE COMMENCING ANY WORK. T/S IRW FIM 26-10 TASK 810 AND WD 26-11-21 FOUND ENG #2 CORE RH LOOP A FAULTY. R/RED LOOP IRW MM 26-11-01 ALL OPS CHECK ARE NORMAL ALSO PERFORMED ENG #2 HIGH POWER AT T/O POWER WITH DIFFRENT PNEUMATIC LOAD ALL PASS. NO FAULT NOTED. MEL REMOVED. ROTABLE PARTS CHANGE WAS INDICATED - TT # 1828433 SN OFF 0032 IPC REFERENCE # 26-11-01