What was found
RIGHT ELEVATOR HAS ONE PUNCTURE DUE TO HAIL, 27 INCHES FROM INBOARD EDGE, 31 1/2 INCHES FROM TRAILING EDGE, 1 INCH DIAMETER COVERED UP REF SRM 55-20-01-1A-1, NO DELAMINATION NOTED OUTSIDE DAMAGE AREA, PROTECTED PUNCTURE WITH SPEED TAPE. LOCKED FOR MAINTENANCE FERRY . PERFORMED BY EMP V902926,RIGHT ELEVATOR PUNCTURE REPLACED AS PER SRM 55-20-01-2R-1 REPAIR 1 TABLE 201 PARA 4D AND 51-70-04-2R-2 REPAIR 2 REV 88,REWORK MOMENT:+2.16 POUND-INCH. RII BY TA405.