What was found
FR 68 HAS CRACK INDICATION AT LH STR 22 IN RADIUS OF HORIZONTAL FLANGE ADJACENT TO LOWER IB DOOR STOP BOLT. GENERATED AT HAECO L CQ PER NR 9290219 (26219) BY V892444 {SUPPORT TASK} 1 WITH NO DEVIATIONS. A DIP IS REQUIRED PER PART 2 TO ACCOMPLIS ILLET RADII AT LH FR68 STR22L PER PART 2A OF THE LATEST REVISION ORM REPEAT INSPT?S NOT TO EXCEED INTERVALS OF 19,700 FC THEREAFT H INITIAL INSPECTION OF REPAIR PART INNER & HORIZONTAL FLANGES F OF ECRA5341-01319 ON OR BEFORE ACFT REACHES 50,764 TTL FC, PERF ER. WHILE ACCOMPLISHING EA5341-01231, NOTED CRACK WAS IDENTIFIED REQ UIRING INTERIM REPAIR PER PART 1 OF ECRA5341-01319 AND REO L2380 REF ECRA 5341-01319 DIP GENERATED TO "ACCOMPLISH INITIAL INSPECT TOMC-APPROVAL FROM SC1ELBYC COMMENT ION ON THE REPAIR PART INNER & HORIZONTAL FLANGES FILLER RADII A T LH FR68 STR22 LHPER PART 2A OF TEH LATEST REVISION OF ECRA 53 41-01319 ON OR BEFORE THE A/C REACHES 50,764 TOTAL A/C FLIGHT CY CLES. PERFORM REPEAT INSPECTIONS NOT TO EXCEED INTERVALS OF 19, 700 FLIGHT CYCLES THEREAFTER". TOMC APPROVES DIP. QC REVIEWED RECORDS UPDATE QC REVIEWED INIT: 50764 TAFC O/C (-4739) WILL ITO TO RIR (-4740) RIR: 19700 FC .....................AZ / U370830