What was found
CORROSION FLOORBEAM +Y1162 LOCATED BTW FR 68 AND FR 69 AT AT AFT GALLEY AREA REMOVED AND REPLACED FLOORBEAM +Y1162 LOCATED BTW FR.68 AND ADDITIONAL DAMAGE ON AREA IAW NTM 51-90-00 FR.69 AT AFT GALLEY AREA IAW A320 SRM 51-72-11 AND DWG D53472000 TOOL USED CALIPER P/N: 500-196-30, S/N: B20244934, DUE DATE: 20-AUG-2022 PERFORMED DETAIL VISUAL INSPECTION AND NO FOUND ENTRY MADE TO REMOVE IP RESTRICTION.