What was found
(B757-53-3-0492) FWD PIT RH SIDE INTERCOSTAL HAS 1EA ELONGATED HOLE AT APPROX STA 725 BETWEEN S27R AND S28R. STREAMER ATTACHED. TRANSCRIBED FROM HAECO GSO NR 9282942 MAT''L ID 7075-0 .032 PO NO. 857 IAW BAC DWG 143N5375 REV C, FORM 51-21-10. INSTALLED INTECOSTAL IAW BOEING DWG 193N5375 REV C AND ED AND HEAT TREATED TO T6 IAW BAC 5602. LOCATED AND DRILLED IAW B757 200 SRM 51 40 02 HAECO GSO MECH V932595 INSP QC467 B757 200 SRM 51-40-02 AND BOEING DWG 143N5375 REV C. ALODINED AN D PRIMED IAW B757 200 SRM 51-20-01 TOPCOATED IAW B757 200 AMM