Service difficulty report · Pump · Boeing 737924ER

Difficulty date
August 10, 2022
Submitted
August 10, 2022
Operation
Air carrier
Aircraft
N37427
Make and model
Boeing 737924ER
Aircraft serial
37097
Aircraft time
44,018 hours, 15,298 cycles
Part
Pump
Part number
849589
Condition
Low Pressure
Location
Eng #1
Stage of operation
CR
How discovered
O
Nature of condition
O
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

ENG 1 LOW PRESSURE LIGHT LIGHT ON ENG DRIVEN NO 1 HYDRAULIC PUMP LOW PRESSURE ILLUMINATED IN FLT. RAN QRH PICTURE ADDED. REMOVED ENGINE NUMBER 1 ENGINE DRIVEN HYDRAULIC PUMP(EDP) PER INFO ONLY HYD PUMP INSTALLED UP TO ITEM I . REF AMM 29-11-11-400-801-001. EC/RA #7900-01440 AND AMM 29-11-11-000-801-001 ROTABLE PARTS CHANGE WAS INDICATED - TT # 1826476 SN OFF 0410 WILL REQUIRE POWERPLANT TEST REF 71-00-00-800-811-F00 ADD EMP:391342 ADD EMP:U032200,U390078,U390203 PUMP, HYD ENG D OFF 29-2910-9-0003 0410 ON 29-2910-9-0003 1896 ACCOMPLISHED OPERATIONAL TEST OF #1 ENG HYD P[UMP REF MM29-11-11-400-801-001. NO LEAKS NOTED DURING TEST