What was found
DURING INSPECTION OF THE AFT ENTRANCE AREA SEVERAL SPOTS OF CORROSION WERE FOUND ON R2 DOOR STILL BTW FR 66-68. (A3NB-53-3-6222, ZONE 262, SEQ#2102) AS NOTED ON LTPR NR# 5001169410-0030. THE REPAIR PERFORMED ON R2 DOOR SILL BEAM FR66 IS MAJOR PERMANENT CATEGORY "A" REPAIR AS PER UAL GMM 03-20-20 REV 156 ADDITIONAL REF:A319 SRM 53-41-14-300-001 PRINCIPLE 2 REV 141. WORK ACCOMPLISHED BY 5H0883/5H0295 AND INSPECTED BY 5H0887.