What was found
DURING HMV VISIT AFT BULK CGO. STR FOUND CORRODED @ FR 60-62 STR. 40R. STRINGER REPAIR WAS ACCOMPLISHED PER SRM 53-00-13-300-001 FIG. 001. LOG CREATED FOR INSPECTION TRESHOLD DIP. INTERVALS: TBD, METHOD: TBD, IAW SRI 53-00-13-205-001 TABLE 004. INSPECTION TRESHOLD FROM TIME OF REPAIR EMBODIMENT 60000 FC/120000 FH WHICHEVER OCCURS FIRST, SUBSEQUENT INSP AT OK TO CARRY PER SRI 53-00-13-205-001, REQUIRES INSPECTION AT TOMC-APPROVAL FROM SC1ELBYC COMMENT 60000F/C''S OR 120000 F/H''S FROM REPAIR EMBODIMENT, WHICH EVER OCCURS FIRST.SUBSEQUENT INSPECTIONS TBD. Q.C REVIEWED. Q/C REVIEWED. INIT: 60,000 FC / 120,000 FH T/A: TBD....AZ/U370830 RECORDS UPDATE