What was found
CORROSION FLOOR BEAM +Y765 LOCATED FR68 TO FR70 AT AFT GALLEY AREA REMOVED AND REPLACED FLOOR BEAM Y765 AND FASTENERS LOC FR66 TO F P/N: 20915A22 S/N: 003591 DUE DATE 30-MAY-2023 R70 AT AFT GALLEY AREA IAW SRM A320 51-42-11, DWG D53472000, DWG 53472092 AND DWG 53474250 TOOL USED DIGITAL CALIPER PN: 500-752 -20 SN: B21038255 DUE DATE 10-AUG-2022, DEPTH GAGE ENTRY MADE TO REMOVE IP RESTRICTION. ACCOMPLISHED WITH AEROMAN NON ROUTINE 2022-308747 UPDATING SRM A320 51-72-11 ADD EMP:V939311