What was found
CORROSION FOUND ON STRINGER 26 RIGHT . DIRECTLY AFT OF FRAME 70. CORROSION LOCATION IS FRAME 67-STRINGER 27 PER SRM ENGINEERING UPDATE, IT IS STRG 26R 53-41-13-50-A. REMOVED STRINGER 26 RIGHT . DIRECTLY AFT OF FRAME 70.AND ASSOCIATED FASTNER FWD OF F.S 70 STR 26R PER SRM 51-42-11/001 UPDATE TO CAPTURE SDR AND MAJOR REPAIR. LOCATED AND DRILLED SPLICE ANGLE D5348004621301 AS PER SRM REMOVED STR 26R PN# D5348004720200 AT F.S 67 AND FWD TO F.S 64 51-44-11/001 PER SRM 51-42-11. POSITION AND DRILLED FULL SIZE NEW STR 26R PN# D5348004720200 / PER SRM 51-42-11.