What was found
FOUND CORROSION AT STR 26R END FITTING AT FRAME FR70. SEE ATTACHED PICTURES. PICS ADDED DAMAGE IS 9 INCHES LONG PROTEUDIMG FORWARD FROM FRAME 70 ON CORROSION LOCATION IS ON FRAME 67-STRINGER 27 SRM ENGINEERING UPDATE, IT IS STR 26R STRINGER 26 R/H 53-41-13-50-A. FIGURE B UPDATE TO CAPTURE SDR AND MAJOR REPAIR. REMOVED FRAME SECTION F.S 67, 25 INCH LONG BETWEEN STR 24R THRU 30R , ALSO REMOVED FRAME SPLICE F.S 67 AT STR 30R. PER SRM 51-42-11. REMOVED RII, NOT A MAJOR REPAIR PREPARED AND INSTALLED 25INCH LONG FRAME SECTION AND ALSO FRAME SPLICE STR 24R-STR 30R SPLICE STR 30R, INSTALLED 75% FASTNERS COMMON TO THE FRAME AND SPLICE. AND SKIN / PER SRM 51-42-11.