ECAM CAUTION MESSAGE - G RSVR LO LVL MESSAGE INOP - HYD FOUND LEFT MLG DOOR ACTUATOR LEAKING AND MLG DOOR BYPASS VALVE STUCK IN BYPASS. DOOR ACTUATOR M&E 31-3231-9-9003 IPC REF 32-31-03-60B. BYPASS VALVE M&E 31-3231-9-9002 IPC REF 32-31-03-46 ITEM 90. REMOVED AND REPLACED LEAKING MLG DOOR ACTUATING CYCLINDER PER PRESSURE. ALL OPS CHECK GOOD. AMM TASK ,32-31-35. REFILLED GREEN HDY RESV. RAN DOOR 5 CYCLES ROTABLE PARTS CHANGE WAS INDICATED - TT # 1258240 SN OFF 8999 UP AND DOWN AND CYCLED ALL HDY SYSTEMS. NO LEAKS AND NO MESSAGE CAME UP GREEN SYSTEM PRESSURE AND QUANTITY HELD NO DROP IN ACTUATOR, MLG D OFF 31-3231-9-9003 8999 ON 31-3231-9-9003 8496