What was found
PASSENGER CABIN, BETWEEN FR20 AND Y-1732, FLOOR STR HAS CORROSIO N. REMOVED CORROSION ON FLOOR STR WEB IAW 51-74-00, FOUND TO BE OUT STA: ST ENG BFM OF LIMITS L=0.849", W=0.550", D=0/060", REMOVED WEB BETWEEN FR2 0 AND Y-1732 IAW SRM 51-42-11 AND INSTALLED NEW WEB FLOOR STR BE TWEEN FR20 AND Y-1732 IAW SRM 51-42-11. EMP: V933986 WC: 36247