What was found
"STRUCTURAL REPAIR CONFORMITY INSPECTION" ITEM 53 CORROSION WAS FOUND ON STR41RH BETWEEN FR30 AND FR34 OF FWD COMPARTMENT PER HA ECO LCQ NON ROUTINE 9296812/42812 GENERATED BY V061680 854 & 33468 FH. REPAIR IS CAT B & REQUIRES REINSP AT 60000FC & 1 CTS FOUND DURING CONFORMITY OF ECRA 5100-03043 INSP: LC30REINSP 20000FH WHICHEVER OCCURS FIRST PER SRI 53-21-13-205-012. NO DEFE BASED OFF REPAIR EMBODIMENT WOULD BE @ 77854PTC 153468PTT INSPECTED & VERIFIED REPAIR ON STR42R BTW FR30-34 WAS ACCOMPLISH ED PER 319 SRM 53-21-13-283-001. TIME OF REPAIR EMBODIMENT FC 17 DIP 53-DIP SRM 53-21-13-283-001 SHOWS NOT EFFECTIVE FOR THIS AIRCRAFT. PLEASE SEE SRM 42-21-13-283-004 CORRECTION TO ABOVE TEXT, WHERE "42RH" SHOULD READ "41RH" REPAIRED STRINGER 41RH BETWEEN FR30 AND FR34 IN FWD CARGO IAWSR M 53-21-13-300-012 REPAIRED TOP COAT IAW SRM 51-75-12-911-002 ME CH V935356