What was found
MASTER WARNING LIGHTS AT THOTTLE ADVANCEMENT ON TAKEOFF NO EICAS MESSAGE CYCLED BREAKERS FOR WARNING ELECTRONIC UNIT BITE CARRIED OUT PER 32-09-00/101 FIG 103 AND CARD 005 IS AT FAULT, REPLACED PSEU PER FIM 31-51 FAULT TREE 804 WITH NO FAULTS FOUND, ALSO BITE TEST AMM 32-09-04 AND ALL TEST PASSED. LND CONFIG TEST, T/O CONFIG CARRIED OUT FOR STALL WARNING BITE MODULE PER 27-32 FAULT TREE TEST, STALL WARNING TEST ALL PASSED NOW. OK TO CONTINUE 803 AND FOUND CODE 27 THAT SENDS US TO BITE PSEU BOX PER ROTABLE PARTS CHANGE WAS INDICATED - TT # 1105485 SN OFF 0599 IPC REFERENCE # 32-09-04-01B UNIT, ASSY, PRO OFF 76-3260-9-0005 9007 ON 76-3260-9-0005 0518