What was found
CTR FUSELAGE LH FR 36 PRESSURE PANEL CRACKED I/B HOLES #9, #20, #26 ACCOMPLISHED ON VTMAE NR 36413 BY VTMAE EMPLOYEE V933870. N PRESSURE PANEL HOLES AREA PER PART 2 OF THE LATEST REVISION OF OR BEFORE MARCH 23, 2023, PERFORM AN INSPECTION OF THE LH FR 36 ECRA 5331-02963. PERFORMED INTERIM REPAIR OF CTR FUSELAGE LH FR 36 PRESSURE PANEL CRACKED I/B HOLES #9, #20, #26 AS PER ECRA 5331-02963. WORK ADD EMP:V933870 CARRY APPROVED PER ECRA 5331-02963. ON OR BEFORE MARCH 23, 2023, TOMC-APPROVAL FROM SC1ELBYC COMMENT PERFORM INSPECTION OF LH FR 36 PRESSURE PANEL HOLES AREA PER PART 2 OF THE LATEST REVISION OF ECRA 5331-02963. INSPECTION ACCOMPLISHED ON ST ENINEERING NRC 36413 RECORDS UPDATE.....JM/U366569 T/A : 23 MAR 2023........JM/U366569 QC REVIEWED QC REVIEWED