What was found
EMERGENCY LIGHTING SYSTEM OPERATIONAL CHECK {B737-33-3-0235} - BOTH EMERGENCY EXIT LIGHTS ABOVE DOOR 1 RT. ARE INOP DURING EMERGENCY LIGHT TEST. REPLACED DOOR 1R EMERGENCY BATTERY PACK - NO HELP,SWAPPED BATTERY PACK W/ DOOR 1L- NO HELP. REINSTALLED BATTERY PACK FOR DOOR 1R. T/S PER WDM 33-51-12-4 FOUND PLUG D2968 DISCONNECTED. RECONNECTED PLUG D2968 AND PREFORMED OPS CHECK OF EMERGENCY LIGHT REF AMM 33-51-00 OPS CHECK GOOD OF EMERGENCY LIGHTS, NO FAULTS NOTED.