As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
L/H FR16 DOOR STOP #7 HOLES 1&3 HAVE CRACK INDICATIONS IN INTERC OSTAL AND FRAME AT 3 O CLOCK "REPAIR BEFORE NEXT FLIGHT" SUPPORT TASK AD RELATED (AD 2022-02-11) GENERATED AT HAECO LCQ PER NR 9 292408 (42408) BY V061632 REMOVED AND REPLACED INTERCOSTAL AND REAMED HOLE 3 (FR LAYER) PE R R53113118, A319 SRM 51-72-11/001, 51-44-11/001. ACP BY V080280 INSP BY V077960.