As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
*EMERGENCY DECLARED*FIRST OFFICERS WINDOW HEAT ARCED AND THEN CRACKED/SPIDER WEBBED ATTACHED PICS FOR F/O WINDOW. REQUIRED RPLCMT REPLACED WINDSHIELD AS PER AMM 56-11-11 PB401. OPS CHK OK FOR SVC. NO LEAKS NOTED AT THIS TIME ADD EMP:U362339 ROTABLE PARTS CHANGE WAS INDICATED - TT # 1821496 SN OFF 6452 ACCOMPLISHED INSPECTION OF REM/INST PROCEDURE OF R1 WINSHIELD REF AMM 56-11-11 PB401. OPS CHK OK FOR SVC. LEAK CHK NO LEAKS NOTED AT THIS TIME. WINDSHIELD, B73 OFF 29-5612-9-9008 6452 ON 29-5612-9-9008 6520