What was found
ACCOMPLISHED DVI OF RIGHT HAND INBOARD FLAP FOUND REPAIR ON UPPE R SURFACE IN GOOD CONDITION 37" UP FROM TRAILING EDGE AND 16" IN BOARD FROM OUTBOARD EDGE TO CENTER OF REPAIR, REPAIR IS 4" X 16" , TRANSCRIBED FROM HAECO GSO N/R 9284205 REPAIRED R/H INBOARD FLAP UPPER SURFACE IAW B757-200 SRM 57-53-0 1-2R-1, SRM 51-10-02-0G-0, SRM 57-53-01-1A-1, BAC DWG #113N2401 REV -, AND SRM 51-70-10-2R-0, REF HAECO GSO MECH V932808 / INSP QC411