What was found
R/H ELEVATOR UPPER PANEL PRODUCED INDICATIONS OF WATER INGRESS D URING THERMOGRAPHY INSPECTION. INDICATION LOCATION IS 15.5 IN FR OM INBD EDGE AND 24.5IN FWD OF THE T/E. 1 IN WIDTH BY 1.5 IN LEN GTH. GENERATED AT HAECO LCQ PER NR 9298182 (32182) BY V061690. {EA 5520-01462} CUT OUT OUTER SKIN AND CORE ON RH ELEVATOR 15.5 IN FROM I/B AND 24.5 IN FWD OF T/E 1.6 IN DIA ZONE 1 AND APPLIED REPAIR IAW A320 SRM 55-21-11-300-005. CATEGORY A REPAIR. ACP BY V061767 INSP BY V061751.