What was found
SHEAR FITTING AT STATION 540 AND LBL 6.14 IS CRACKED. REMOVED AND REPLACED SHEAR FITTING AT STA. 540 LBL 6.14 IAW SRM 51-40-02 AND DWG 11A2000 REV ORGINAL.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SHEAR FITTING AT STATION 540 AND LBL 6.14 IS CRACKED. REMOVED AND REPLACED SHEAR FITTING AT STA. 540 LBL 6.14 IAW SRM 51-40-02 AND DWG 11A2000 REV ORGINAL.