What was found
FLOOR SUPPORT Y765 FR64 TO FR66 CORRODED AT 2 LOCATIONS. EVALUATED FOR DAMAGE AND FOUND OUT OF LIMIT IAW 53-00-14-283-002 . REMOVED FLOOR BEAM AND INSTALLED NEW FLOOR BEAM IAW SRM 51-42- 71/001. EMP: V940360 WC: 41165 STA: ST ENG BFM
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOOR SUPPORT Y765 FR64 TO FR66 CORRODED AT 2 LOCATIONS. EVALUATED FOR DAMAGE AND FOUND OUT OF LIMIT IAW 53-00-14-283-002 . REMOVED FLOOR BEAM AND INSTALLED NEW FLOOR BEAM IAW SRM 51-42- 71/001. EMP: V940360 WC: 41165 STA: ST ENG BFM