What was found
PDA 3, RH INBOARD FLAP SLOT DOOR FOUND MISSING. APPROVED PANEL PREVIOUSLY INSTALLED! REQUIRES DISASSEMBLING OF THE TUBE DRIVE. DOOR REQUIRES DRILLING HOLES AND INSTALLING HARDWARES TO ATTACH THE HING ASSEMBLY. 2 RIVETS P/N BACR15BB6AD, 4 BOLTS BACB30NN3K5, 4 NUTS MS21042L3, 4 WASHERS P/N AN960JD10L. NOT ENOUGH GROUND TIME TO ACCOMPLISH TASK. UPDATED MATERIALS AND LABOR. IPC 27-51-03-21. DOOR, ASSY NOT IN STOCK AT EWR UNABLE TO WORK ITEM. INSTALLED PIVOT ARM AND FWD DOOR. REF SRM 52-40-02