What was found
SPD LIM INTERMITANT ON CA SIDE AT LEVEL 380 GOT OVERSPD INDICATI ONS PER FLT CREW, STICK SHAKER ALSO ACTUATED INTERMITTANTLY IN "0" ON #1 SMYD. #1 DEU, ADIRU AND SMYD ALL SELF TESTED NORMAL. CONJUNCTION WITH THE "SPD LIMIT" FAULT AND OVERSPEED INDICATION R/R''D CAPT''S AOA SENSOR PER AMM 34-21-05, OPS CHKS GOOD. NOTE: (ALL ON CAPT''S SIDE). T/S PER FIM TASKS 27-32-T809, T831 AND SMYD NIS GUM AT THIS TIME (59-2732-9-0001). PARTS USED: T834, FOUND CAPT''S SIDE AOA SENSOR SIGNAL ERROR FAULT ON FLT LEG 29-3412-9-0001,QTY :1 ROTABLE PARTS CHANGE WAS INDICATED - TT # 1004029 SN OFF 2227 SENSOR, ANGLE O OFF 29-3412-9-0001 2227 ON 29-3412-9-0001 3604