What was found
SELECTED FLAPS ONE. GOT TRAILING EDGE DISAGREE. QRH RUN. UNEVENT FUL LANDING. REPLACED FLAP STAB MODULE.PARTS USED:76-2754-9-0001,QTY :1ROTABLE PARTS CHANGE WAS INDICATED - TT # 1147533 SN OFF 2812 FIM TASK 27-51 FAULT TREE 810 ACTIONED, FSEU BITE TEST SHOWED L FSPM INACTIVE FAULT ON LAST LEG. FSPM BITE TEST CARRIED OUT IAW FIM TASK 27-58 FAULT TREE 804, L FSPM TESTED OKAY BUT REPLACED AS PRECAUTION IAW AMM 27-58-01. MCDP TEST 64 CARRIED OUT AND TEST OKAY. FLAPS CYCLED UP AND DOWN BOTH HYDRAULICALLY AND ELECTRICALLY. UNABLE TO REPLICATE FAULT.