What was found
STATUS MSG PACK ACM L AFTER LANDING L/H ACM SEIZED, FAILED TORQUE CHECK, REF FIM 21-52 TASK 818. REMOVED ACM L PER AMM 21-52-02 COMPLETED INSTALLATION OF ACM IN REF TO AMM 21-52-02-400-801 UP TO ITEM J, ACM INSTALLATION TEST PASSED AND CONDENSER TEST ACCEPTABLE. PARTS USED: 27-2111-9-0001,QTY :1 ADD EMP:U108974,U393448 ROTABLE PARTS CHANGE WAS INDICATED - TT # 1152175 SN OFF 0017 IPC REFERENCE # 21-52-02-01 ACCOMPLISHED OIL CONTAMINATION REMOVAL FROM AIR CONDITIONING AND PNEUMATIC SYSTEMS. IAW AMM 21-00-01-100-801 OPS CK GOOD. NO SMELL IN THE WHOLE CABIN AND OR SIGNS OF EXHAUST GASES. MACHINE, AIR CY OFF 27-2111-9-0001 8017 ON 27-2111-9-0001 1078