What was found
DURING HMV4 VISIT AT BFM ACCOMPL''G EA5341-01231 (B) CRACKS WERE FOUND AT FR68 LH STGR 22 WEB HORIZ FLANGE UPPER & LWR BOTTOM RADIUS. ADDITIONALLY, WHILE ACCOMPL''G EA5340-01724(C) OP2 A CRACK WAS NOTED AT FR68 LH DOOR STOP FITTING #1 WORK ACCOMPLISHED ON VTAERO N/RS 45467 & 45724 EA IS INCLUDED WITHIN THIS ECRA. ECRA REQUIRES DIP THAT STATES T ENGINEERING FOR INSPECION REQUIREMENTS PER PART 2 OF THE LASTE 800/003/2023#A FOR NECESSARY INSPECTIONS. ON OR BEFORE ACFT 4248 REACHES 45,000 TTL FC, PLANNING TO CONTAC ST REVISION OF ECRA5341-01369. ENGINEERING REFER TO RDAF 81170 ACCOMPLISHED INTERIM REPAIR PER PART 1 OF ECRA5341-01369 REV ''A'' AND VT MAE EA320-5341-13-A3104 FINAL WITH NO DEVIATIONS. VT MAE LOG PAGE IS FOR DIP REPORTING