What was found
DOOR-MOUNTED ESCAPE SYSTEM DOOR 2L - A EVACUATION SLIDE PROBLEM WAS ENCOUNTERED WHICH IS NOT COVERED IN THE FAULT CODE DIAGRAMS DOOR ARM LIGHT INTERMITTENT WITH 2L DOOR CLOSED AND ARMED INSPECTED DOOR 2L AND FOUND GIRT BAR LANYARD IMPEEDING 52-11-02-904-004. OPERATION. STOWED GIRT BAR LANYARD IN CORRECT LOCATION. PREFORED OPS CHECK. DOOR OPPERATES NORMALLY , ALL INDICATIONS NORMAL. ACFT OK FOR SVC. REF AMM 52-11-00-206-021 AND AMM