What was found
APU SHUTDOWN EICAS ADVISORY APU AUTO-SHUTDOWN HAS OCCURRED. APU SURGE BLEED SYSTEM SENSORS FOUND COMPLETELY CLOGGED. THE CIFFERELLO ADDITIONAL MESH FILTER SCREEN LOCATED AT THE INLET PRESSURE CLEARED BLOCKAGES FROM PNEUMATIC LINES AND CLEANED THE INTAKE 40-11-00-740-801. MESH SCREEN FILTER. REPLACED DIFFERENTIAL PRESSURE SENSOR (REF. ROTABLE PARTS CHANGE WAS INDICATED - TT # 1869107 SN OFF 0010 AMM: 49-53-04/401 & 49-53-53). OPS CHECK NORMAL. NO MAINTENANCE FAULT MESSAGES DISPLAYED AT THIS TIME. REF. AMM: ADD EMP:U399271, SENSOR, ASSY, D OFF 25-4953-9-0002 0010 ON 25-4953-9-0002 3463