R STARTER CUTOUT MESSAGE ON EICAS DURING CLIMB OUT AS PER FIM TASK 80-11-02/401. R ENGEINE START VALVE REQUIERES. REMOVAL. REMOVED AND REPLACED R ENGINE STARTE S/O VALVE AS PER MM 80-11-02-004-001-NOO. OPS. CHECK GOOD. AIRCRAFT OK TO CONTINUE. PARTS USED: 76-8012-9-0001,QTY :1 1096271,QTY :1 ROTABLE PARTS CHANGE WAS INDICATED - TT # 1096271 SN OFF 0149 VALVE, SHUTOFF, OFF 76-8012-9-0001 0149 ON 76-8012-9-0001 1072