What was found
LH FR 16 CROSSBEAM HOLE H2,H3 AND H4 HAVE CRACK INICATIONS IN FR AME LAYER PER HAECO LCQ N/R 9298767/40767 GEN BY V892444 CROSSBEAM JUNCTION HOLES #H2, H3, H4 PER PART 2 OF THE LATEST 67384 TOTAL AIRCRAFT CYCLES. REVISION OF ECRA 5310-08147 ON OR BEFORE THE AIRCRAFT REACHES ACCOMPLISHED INTERIM REPAIR IAW ECRA 5310-08147 WITH NO DEVIATIONS. ACCOMPLISH INITIAL INSPECTION AT THE LH FR16 REF ECRA 5310-08147 INTERIM REPAIR STEP 2. "ACCOMPLISH INITIAL TOMC-APPROVAL FROM SC1ELBYC COMMENT INSPECTION AT THE LH FR16 CROSSBEAM JUNCTION HOLES #H2, H3 AND H4 PER PART 2 OF THE LATEST REVISION OF ECRA 5310-08147 ON OR BEFORE THE AIRCRAFT REACHES 67,384 TOTAL AIRCRAFT FLIGHT CYCLES." INSPECTIONS CREATED BY AUTODIP PENDING AIRCRAFT RECORDS AUDIT & UPDATE.