What was found
SHEAR FITTING AT STATION 540 AND LBL 6.14 IS CRACKED. SUPPORT TASK NSA EMX N/R 00075. N/R 5867106, WORK ACCOMPLISHED BY V931802 AND INSPECTED BY V912634. REMOVED AND REPLACED SHEAR FITTING AT STATION 540 AND LBL 6.14 IAW B737-800 SRM 51-40-02 AND BAC DWG 111A2000 REV ORIGINAL. SEE NSA EMX N/R 00075 AND HANGAR N/R 5867106 FOR WORK ACCOMPLISHED. CIR C/W. DATA WAS TRANSCRIBED FROM NSA EMX N/R 00075, AND HANGAR ADD EMP:V931802 INSPECTION COMPLETE SSFR REPORT, FORM 46-0024, ENTERED BY UAL INSPECTION U355204. DATE 05/03/2023 INSPECTION COMPLETE