What was found
SHEAR FITTING AT STATION 540 AND LBL 40.87 IS CRACKED. SUPPORT TASK NSA EMX N/R 00077. N/R 5867108, WORK ACCOMPLISHED BY V931802 AND INSPECTED BY V912634 REMOVED AND REPLACED SHEAR FITTING AT STATION 540 AND LBL 40.87 IAW B737-800 SRM 51-40-02 AND BAC DWG 111A2000 REV ORIGINAL. SEE NSA EMX N/R 00077 AND HANGAR N/R 5867108 FOR WORK ACCOMPLISHED. CIR C/W. DATA WAS TRANSCRIBED FROM NSA EMX N/R 00077, AND HANGAR INSPECTION COMPLETE SSFR REPORT, FORM 46-0024, ENTERED BY UAL INSPECTION U355204. DATE 05/03/2023 INSPECTION COMPLETE