What was found
ENG 1 COMP VANE FAULT REF TSM TASK 75-30-00-810-852-A ENG 1 VSV INTERACTION ISSUE. PRIOR HISTORY 4/28 CHS, 2/21 BFM (MASTER ACTUATOR RPL) COMPLEATED TASK75-32-41 UP TO STEPS D3. STEPS J3 TO STEP 5 UPDATED PARTS PFR PICS ADDED. COMPLETED. STEPS D3(A) TO H1 NEEDS TO BE COMPLETED. THEN LEAK ADD EMP:U399273 CHECKED PARTS USED: 18-7311-3-0052,QTY :1 ROTABLE PARTS CHANGE WAS INDICATED - TT # 1771710 SN OFF 5577 40-0596-3-6228,QTY :1 31-7532-9-0002,QTY :1 ACTUATOR, VARIA OFF 31-7532-9-0002 5577 ON 31-7532-9-0002 0028 COMPLETED AMM 75-32-41 STEP D3 TO AND INCLUDING H (1) NEEDS LEAK CHECK AND HIGH POWER ASSURANCE RUN PERFORMED LEAK CHECK REF AMM 71-00-00, NO LEAKS NOTED. PERFORMED HIGH POWER ASSURANCE TEST REF AMM 71-00-00, ALL PARAMETERS WITHIN LIMITS.