What was found
LH HORIZONTAL STAB LOWER SKIN 11/16" CRACK AT STA 147.90 AT NO. 8 DRAIN HOLE. REF TO PEMCO NR 13826.0314 REPAIRED L/H HORIZONTAL STAB LOWER SKIN AT STA 147-90 AT NO.8 DR AIN HOLE DIMENTIONS OF REPAIR 12X9 IAW B737 SRM 55-10-01-2R-11 R EPAIR 11 REQ INSPECTION AT 56,000 TOTAL FLIGHT CYCLES. COMPLETED BY V935715, INSP BY Q945, ENTERED BY V928371. RE-INSP BY Q878.