What was found
RH EMER.EXIT ESCAPE HATCH RH LOAD LIMITING FROFIL CRACKED AT FAS TENER HOLES. REMOVED RH INTERCOSTAL IAW SRM 51-42-11, RECEIVVE NEW SEGMENT AN AND RESTORED SURFACE PROTECTION IAW SRM 51-75-11/001. EMP: V9363 GLE P/N D5227902620551, BATCH# 0004061454, LOCATED ANDDRILLED IA 22 WC: 56341 STA: ST ENG BFM W SRM 51-44-11, INSTALLED NEW SEGMENT IAW SRM 51-42-11, TREATED AND PRIMED IAW SRM 51-21-11, APPLIED TOP COAT IAW SRM 51-75-12